new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

May 5

High-Fidelity Digital Twin Dataset Generation for Inverter-Based Microgrids Under Multi-Scenario Disturbances

Public power-system datasets often lack electromagnetic transient (EMT) waveforms, inverter control dynamics, and diverse disturbance coverage, which limits their usefulness for training surrogate models and studying cyber-physical behavior in inverter-based microgrids. This paper presents a high-fidelity digital twin dataset generated from a MATLAB/Simulink EMT model of a low-voltage AC microgrid with ten inverter-based distributed generators. The dataset records synchronized three-phase PCC voltages and currents, per-DG active power, reactive power, and frequency, together with embedded scenario labels, producing 38 aligned channels sampled at Δt = 2~μs over T = 1~s (N = 500{,}001 samples) per scenario. Eleven operating and disturbance scenarios are included: normal operation, load step, voltage sag (temporary three-phase fault), load ramp, frequency ramp, DG trip, tie-line trip, reactive power step, single-line-to-ground faults, measurement noise injection, and communication delay. To ensure numerical stability without altering sequence length, invalid samples (NaN, Inf, and extreme outliers) are repaired using linear interpolation. Each scenario is further validated using system-level evidence from mean frequency, PCC voltage magnitude, total active power, voltage unbalance, and zero-sequence current to confirm physical observability and correct timing. The resulting dataset provides a consistent, labeled EMT benchmark for surrogate modeling, disturbance classification, robustness testing under noise and delay, and cyber-physical resilience analysis in inverter-dominated microgrids. The dataset and processing scripts will be released upon acceptance

  • 3 authors
·
Mar 9

NILMFormer: Non-Intrusive Load Monitoring that Accounts for Non-Stationarity

Millions of smart meters have been deployed worldwide, collecting the total power consumed by individual households. Based on these data, electricity suppliers offer their clients energy monitoring solutions to provide feedback on the consumption of their individual appliances. Historically, such estimates have relied on statistical methods that use coarse-grained total monthly consumption and static customer data, such as appliance ownership. Non-Intrusive Load Monitoring (NILM) is the problem of disaggregating a household's collected total power consumption to retrieve the consumed power for individual appliances. Current state-of-the-art (SotA) solutions for NILM are based on deep-learning (DL) and operate on subsequences of an entire household consumption reading. However, the non-stationary nature of real-world smart meter data leads to a drift in the data distribution within each segmented window, which significantly affects model performance. This paper introduces NILMFormer, a Transformer-based architecture that incorporates a new subsequence stationarization/de-stationarization scheme to mitigate the distribution drift and that uses a novel positional encoding that relies only on the subsequence's timestamp information. Experiments with 4 real-world datasets show that NILMFormer significantly outperforms the SotA approaches. Our solution has been deployed as the backbone algorithm for EDF's (Electricit\'e De France) consumption monitoring service, delivering detailed insights to millions of customers about their individual appliances' power consumption. This paper appeared in KDD 2025.

  • 4 authors
·
Jun 6, 2025

Learning Distribution Grid Topologies: A Tutorial

Unveiling feeder topologies from data is of paramount importance to advance situational awareness and proper utilization of smart resources in power distribution grids. This tutorial summarizes, contrasts, and establishes useful links between recent works on topology identification and detection schemes that have been proposed for power distribution grids. The primary focus is to highlight methods that overcome the limited availability of measurement devices in distribution grids, while enhancing topology estimates using conservation laws of power-flow physics and structural properties of feeders. Grid data from phasor measurement units or smart meters can be collected either passively in the traditional way, or actively, upon actuating grid resources and measuring the feeder's voltage response. Analytical claims on feeder identifiability and detectability are reviewed under disparate meter placement scenarios. Such topology learning claims can be attained exactly or approximately so via algorithmic solutions with various levels of computational complexity, ranging from least-squares fits to convex optimization problems, and from polynomial-time searches over graphs to mixed-integer programs. Although the emphasis is on radial single-phase feeders, extensions to meshed and/or multiphase circuits are sometimes possible and discussed. This tutorial aspires to provide researchers and engineers with knowledge of the current state-of-the-art in tractable distribution grid learning and insights into future directions of work.

  • 3 authors
·
Apr 26, 2023

Energy Injection Identification enabled Disaggregation with Deep Multi-Task Learning

Non-Intrusive Load Monitoring (NILM) offers a cost-effective method to obtain fine-grained appliance-level energy consumption in smart homes and building applications. However, the increasing adoption of behind-the-meter (BTM) energy sources such as solar panels and battery storage poses new challenges for conventional NILM methods that rely solely on at-the-meter data. The energy injected from the BTM sources can obscure the power signatures of individual appliances, leading to a significant decrease in NILM performance. To address this challenge, we present DualNILM, a deep multi-task learning framework designed for the dual tasks of appliance state recognition and injected energy identification. Using a Transformer-based architecture that integrates sequence-to-point and sequence-to-sequence strategies, DualNILM effectively captures multiscale temporal dependencies in the aggregate power consumption patterns, allowing for accurate appliance state recognition and energy injection identification. Extensive evaluation on self-collected and synthesized datasets demonstrates that DualNILM maintains an excellent performance for dual tasks in NILM, much outperforming conventional methods. Our work underscores the framework's potential for robust energy disaggregation in modern energy systems with renewable penetration. Synthetic photovoltaic augmented datasets with realistic injection simulation methodology are open-sourced at https://github.com/MathAdventurer/PV-Augmented-NILM-Datasets.

  • 6 authors
·
Aug 20, 2025